MODEL |
LDA100VA-12/LDA100VA-24 |
|
OUTPUT |
DC VOLTAGE |
12V/24V |
RATED CURRENT |
8.5A/4.7A |
|
RATED POWER |
100W |
|
RIPPLE & NOISE (max.) Note.2 |
150mVp-p |
|
VOLTAGE ADJ. RANGE Note.5 |
10.8 ~ 13.2V/22.4 ~ 25.6V |
|
VOLTAGE TOLERANCE Note.3 |
±2.0% |
|
LINE REGULATION |
±0.5% |
|
LOAD REGULATION |
±1.5% |
|
SETUP. RISE TIME Note.7 |
2500ms, 80ms at full load 230VAC /115VAC |
|
HOLD UP TIME (Typ.) |
16ms at full load 230VAC /115VAC |
|
INPUT |
VOLTAGE RANGE |
90 ~ 264VAC |
FREQUENCY RANGE |
47~63HZ |
|
EFFICIENCY (Typ.) |
93% |
|
AC CURRENT (Typ.) |
20A / 230VAC |
|
INRUSH CURRENT (Typ.) |
COLD START 75A/230VAC |
|
LEAKAGE CURRENT |
<0.75mA / 277VAC |
|
PROTECTION |
OVER LOAD PROTECTION |
95 ~ 108% |
130% constant current limited, auto-recovery |
||
SHORT CIRCUIT |
Hiccup mode, recovers automatically after fault condition is removed |
|
ENVIRONMENT |
WORKING TEMP. |
-40 ~ +70°C(Refer to "Derating Curve") |
WORKING HUMIDITY |
20 ~ 95% RH non-condensing |
|
STORAGE TEMP., HUMIDITY |
-40 ~ +80°C, 10 ~ 95% RH |
|
VIBRATION |
10 ~ 500Hz, 5G 12min./1cycle, period for 72min. each along X, Y, Z axes |
|
SAFETY&EMC |
SAFETY STANDARDS Note.7 |
IP67, CE approved |
WITHSTAND VOLTAGE |
I/P-O/P:3.75KVAC I/P-FG:1.88KVAC O/P-FG:0.5KVAC |
|
ISOLATION RESISTANCE |
100w waterproof switching power supply |
|
EMC EMISSION |
Compliance to EN55015, EN55022 (CISPR22) Class B, EN61000-3-2 Class C (≥50% load) ; EN61000-3-3 |
|
EMC IMMUNITY |
Compliance to EN61000-4-2,3,4,5,6,8,11, EN61547, EN55024, light industry level (surge 4KV), criteria A |
|
OTHERS |
WARRANTY |
Two years after delivery the goods |
DIMENSION |
222*68*43mm |
|
PACKING |
N.W: 0.75Kg G.W: 15.78 (1pcs per white box, 23pcs per carton ) Carton size: 505*370*315mm |